Gem Equipments, Compressed Air & Cooling System

GEM Equipments Limited » Products » Refrigrated Air Dryers » RAD Series

 
Compact Refrigrated Air Dryers - 2KD Series

Specifications

SALIENT FEATURES

» Shell and Copper tube heat exchanger
» Efficient Power saving
» Non-Cyclic system with provision of hot gas bye-pass valve
» HP,LP, WP Overload safety trips
» Range from 2500 CFM to 5000 CFM

The basic principle of operation of the Refrigerated Air dryer is the removal of moisture by cooling air to certain present temperature. There is no process known for producing cold, there is only heat removal. Heat is always attracted by the cold body. This is the basis for the operation of a cooling unit. As long as the temperature of the cold body is lower than the hot source, there will be heat transfer.

The air entering the system enters into the precooler. A precooler is a heat exchanger where the incoming hot air is being cooled by the outgoing cold air so as to reduce the heat load for the evaporator and thereby the refrigeration system. The air from the precooler enter into the evaporator. In evaporator the cooling, heat removal is done by the boiling refrigerant. The air with condensate, enters into moisture separator, where the moisture is removed by the centrifugal action of air. The air free from moisture enters the precooler to cool the incoming air and thereby some heat is added.

The refrigerant circuit consists of a Compressor, a Condensor, a Filter Dryer, an Expansion Valve or a Capillary Tube and an Evaporator.

 

 
COMPRESSED AIR DRYERS
& ACCESSORIES
Refrigeration Air Dryers
» Compressed Refrigerated Air Dryer
» Wall Mounted Refrigerated Air Dryer
» High Pressure Refrigerated Air Dryer
» Refrigerated Air Dryer
Desiccant Air Dryers
» SPD Series Heatless Air Dryer
» Heatless Air Dryer
» Heatless Desiccant Air Dryer
Air Treatment Accessories
» Moisture Separator
» Compressed Air Filter
» Automatic Drain Valve
» Water Cooled After Cooler
» Air Cooled After Cooler
» Compressed Air Receiver
 
COOLING TOWERS
FRP / Evaporative Cooling Towers
» Bottle Cooling Tower
» Square Cooling Tower
» Cross Flow Cooling Tower
» Evaporative Coil Cooling Tower
» Modular Cooling Tower
» Double Cross Flow Cooling Tower
Dry Cooling Towers
» Dry Cooling Tower
» Aqua Saver
 
INDUSTRIAL COOLERS
» Refrigeration Industrial Chiller
 
Technical Specifications:
Model
CFM
m3/hr
Rated
Power
Air Connection
Dimensions
in mm
Weight
in Kg
L
W
H
RAD-250
2500
4250
7.5Kw
6" NB ANSI  B 16.5 150# Flg
2250
1300
1850
1750
RAD-300
3000
5100
10 Kw
6" NB ANSI  B 16.5 150# Flg
2500
1300
1960
2500
RAD-350
3500
5950
15 Kw
8" NB ANSI  B 16.5 150# Flg
2750
1400
1960
3250
RAD-400
4000
6800
15 Kw
8" NB ANSI  B 16.5 150# Flg
2750
1400
1960
3250
RAD-500
5000
8500
18 Kw
10" NB ANSI B 16.5 150# Flg
3500
1750
1750
3250


Working
Pressure
Bar (g) 12.5
PSI (g) 180
Electricty Connection 415V, 3Ø, 50Hz
Refrigerant R22

* Product Design and specifications are subject to change due to constant upgradation.