Welcome to Gem Equipments.

sales@gemindia.com - 9344455927

service@gemindia.com - 9366631697

Automatic Drain Valve

Designed to drain sludge and rust laden condensate in compressor room equipment and pipeline.

SALIENT FEATURES:

  • Zero Air Loss
  • No Electricity and Noise
  • Robust Design
  • Manual Discharge
  • Cleanable Orifice
  • Float type

The offered product is designed to drain sludge and rust laden condensate in compressor room equipment and pipeline. The digital electronic circuitry is encapsulated in high-grade resin for absolute time control. The valve comes with settings which gives the power and drain status indicator. It also has a waterproof IP 55 enclosure for suitable outdoor installations.

Download Brochure
Automatic Drain Valve

SALIENT FEATURES:

  • Designed especially to drain sludge and rust laden condensate in compressor room equipment and pipeline.
  • Reliable all Digital electronic circuitry encapsulated in high grade resin for absolute time control.
  • Easy settings for variable Cycle time with Power and Drain status indicator.
  • Water - Proof IP 55 enclosure suitable for outdoor installations.

Technical Specification

GZ - HD

Accessories

  • Stainer
  • Pilot Tubing
  • Connector Tubing
SPECIFICATIONS
Valve opening interval 0.5-35 min (adjustable)
Valve discharge 0.5-20 sec (adjustable)
Power consumption 10 W
Max. operating temp. 89º C
Max. operating press. 16 bar (g)
Orifice 6 mm
In/Out ports 1/2" BSP
Connector DIN43650A
Environmental protect IP65
Type Pilot operated
Max. discharge at 7 bar 150 lit/hr
Weight 0.5 kg
FEATURES & APPLICATIONS
Features Applications
Universal Voltage and Frequency 'Any where,Any country' Dryers
UNO Piston Receivers
Manual Test switch Filters
Vortex Seperators
For compressors upto 2000 CFM

GZ - LD

Accessories

  • Stainer
  • Connector Tubing
SPECIFICATIONS
Valve opening interval 0.5-35 min (adjustable)
Valve discharge 0.5-20 sec (adjustable)
Power consumption 10 W
Max. operating temp. 90º C
Max. operating press. 16 bar (g)
Orifice 3 mm
In/Out ports 1/2" BSP
Connector DIN43650A
Environmental protect IP65
Type Pilot operated
Max. discharge at 7 bar 60 lit/hr
Weight 0.5 kg
FEATURES & APPLICATIONS
Features Applications
Universal Voltage and Frequency 'Any where, Any country' Dryers
Viton Seals in valve for long life Receivers
Filters
Vortex Seperators
For compressors upto 100 CFM

GDV - HD

Accessories

  • Stainer
  • Pilot Tubing
  • Connector Tubing
SPECIFICATIONS
Valve opening interval 1 - 136 min
Valve discharge 4 sec (fixed)
Power consumption 9 W
Max. operating temp. 75º C
Max. operating press. 16 bar (g)
Orifice 12.5 mm
In/Out ports 1/2" BSP
Connector DIN43650A with 2 core rated for 3A
Environmental protect IP55
Type Direct operated
Max. discharge at 7 bar 200 lit/hr
Weight 1 kg
FEATURES & APPLICATIONS
Features Applications
Non Clogging' Dryers
Larger Orifice Receivers
Filters
For compressors upto 3000 CFM

GDV - LD

Accessories

  • Stainer
  • Connector Tubing
SPECIFICATIONS
Valve opening interval 1 - 136 min
Valve discharge 8 sec (fixed)
Power consumption 10 W
Max. operating temp. 75º C
Max. operating press. 16 bar (g)
Orifice 1.3 mm
In/Out ports 1/2" BSP
Connector DIN43650A with 2 core rated for 3A
Environmental protect IP55
Type Direct operated
Max. discharge at 7 bar 29 lit/hr
Weight 0.75 kg
FEATURES & APPLICATIONS
Features Applications
In built Strainer Dryers
Receivers
After Coolers
For compressors upto 60 CFM

GFV - 20

Accessories

  • Stainer
  • Pilot Tubing
  • Connector Tubing
SPECIFICATIONS
Valve opening interval
Valve discharge
Power consumption
Max. operating temp. 90º C
Max. operating press. 20 bar (g)
Orifice 3 mm
In/Out ports 1/2" BSP
Connector
Environmental protect
Type Float operated
Max. discharge at 7 bar 300 lit/hr
Weight 0.9 kg
FEATURES & APPLICATIONS
Features Applications
Zero Air Loss Dryers
No Electricity...No Noise Receivers
Robustic Design Filters
Manual Discharge After Coolers
Cleanable Orifice Vortex Seperators
Float type For compressors upto 3000 CFM

* Product Design and specifications are subject to change due to constant upgradation.