Salient Features
- Work pressure - 16 bar
- Heat exchanger is fully enclosed.
- Compact Size.
- Low power consumption
- Easy for installation
- Corrosion resistance painting
- High Efficiency copper tubes.
- Optional Vortex Separator for 99.99% moisture
removal.
- Continuous duty motor with Aluminium /
highly reliable plastic fans.
- Most suitable for portable applications.
Dryers are sized according to the flow, pressure, temperature and
dew point required of the compressed air. If these conditions are
changed, the resulting efficiency of the dryer can be drastically
affected. The temperature of the compressed air leaving a compressor
varies from 82 °C to 177 °C, depending on the type of compressor,
it is essential that an After Cooler be installed upstream of most
dryers because it will lower the temperature to required level and
will remove 50 to 75% of water vapour contained in the air. After
coolers are available in either air or water cooled units.
Air Cooled After Cooler
Air cooled After Coolers are of fine-tube construction with the
compressed air passing through the tube. Air Cooled After Cooler
transfer the heat from the compressed air to the atmosphere. The
compressed air is cooled using a cooler fan. Air Cooled After Coolers
are preferred because it is easy to install and no additional pipe
lines for water and easy to maintain.
|