Welcome to Gem Equipments.

sales@gemindia.com - 9344455927

service@gemindia.com - 9366631697

Air Cooled Cooler

Designed to drain sludge and rust laden condensate in compressor room equipment and pipeline.

SALIENT FEATURES:

  • Work pressure - 16 bar
  • Heat exchanger is fully enclosed.
  • Compact Size.
  • Low power consumption
  • Easy for installation
  • Corrosion resistance painting
  • High Efficiency copper tubes.
  • Optional Vortex Separator for 99.99% moisture removal.
  • Continuous duty motor with Aluminium / highly reliable plastic fans.
  • Most suitable for portable applications.

Dryers are sized according to the flow, pressure, temperature and dew point required of the compressed air. If these conditions are changed, the resulting efficiency of the dryer can be drastically affected. The temperature of the compressed air leaving a compressor varies from 82 °C to 177 °C, depending on the type of compressor, it is essential that an After Cooler be installed upstream of most dryers because it will lower the temperature to required level and will remove 50 to 75% of water vapour contained in the air. After coolers are available in either air or water cooled units.

Download Brochure
Air Cooled Cooler

Air Cooled After Cooler:

Air cooled After Coolers are of fine-tube construction with the compressed air passing through the tube. Air Cooled After Cooler transfer the heat from the compressed air to the atmosphere. The compressed air is cooled using a cooler fan. Air Cooled After Coolers are preferred because it is easy to install and no additional pipe lines for water and easy to maintain.

Technical Specification

Model Capacity Working Pressure Power Req. Electrical Conn. In/Out Conn. Dimension mm Weight
CFM m³/hr bar Kw 220V 1PH 50 HZ 415V 3PH 50Hz BSP A B C Kg.
ACC003 35 58 16 0.036 tick   1/2" 422 120 727 45
ACC005 50 83 16 0.11 tick   3/4" 513 140 806 50
ACC010 100 170 16 0.24 tick   1 1/2" 622 160 905 75
ACC015 150 255 16 0.24 tick   1 1/2" 622 160 905 75
ACC020 200 340 16 0.24 tick   2" NB FLG 900 230 1080 140
ACC030 300 510 16 0.24 tick   2" NB FLG 900 230 1080 150
ACC040 400 680 16 0.55   tick 2" NB FLG 920 920 1285 200
ACC060 600 1020 16 0.75   tick 3" NB FLG 1000 1080 1055 220
ACC075 750 1275 16 1.5   tick 3" NB FLG 1750 1524 1500 250
ACC100 1000 1700 16 1.5   tick 4" NB FLG 1750 1524 1500 250

Air inlet temperature is 90ºC, Air outlet temperature is 45ºC

* Product Design and specifications are subject to change due to constant upgradation.

NEED HELP?

Live Chat
Agents are offline

send enquiry

captcha